Specifications |
|||
Model |
PR-XI-PS502 |
||
Rated Power |
5000W |
||
Peak Power(20mS) |
15KVA |
||
Standard Battery Voltage |
48VDC |
||
Dimension(L*W*Hmm) |
440x300x110 |
||
Packing Size(L*W*Hmm) |
515x375x205 |
||
Net Weight(Kg) |
9.5 |
||
Gross wight(Kg) |
10.5 |
||
Installation Style |
Wall-mounted |
||
PV |
Operation Mode |
MPPT |
|
Rated PV Input Voltage |
360VDC |
||
MPPT Tracking Voltage Range |
120V-430V |
||
Maximum PV Input Voltage |
450V |
||
(At the lowest temperature) |
|||
Maximum PV Input Power |
5500W |
||
MPPT Tracking Wiring |
1 |
||
Input |
Dc Input Voltage Range |
42VDC-60VDC |
|
Rated Grid Input Voltage |
208VAC/220VAC/230VAC/240VAC |
||
Grid Input Voltage Range |
90VAC~280VAC(Appliance mode)/170VAC~280VAC(UPS mode) |
||
Grid Input Frequency Range |
40Hz~70Hz (Default) |
||
Output |
Inverter Output Efficiency |
94%(Peak) |
|
Inverter Output Voltage |
208VAC±2%/220VAC±2%/230VAC±2%/240VAC±2%(Inverter Mode) |
||
Inverter Output Frequency |
50Hz/60Hz±0.1% |
||
Inverter Output Waveform |
Pure Sine Wave |
||
Grid Output Efficiency |
>99% |
||
Grid Output Voltage Range |
90VAC~280VAC(Appliance mode)/170VAC~280VAC(UPS mode) |
||
Grid Onput Frequency Range |
40Hz~70Hz (Default) |
||
Inverter Output Waveform Distortion |
≤3%(Linear Load) |
||
Battery Mode Open Circuit Loss |
≤1%Rated Power |
||
Grid Mode Open Circuit Loss |
≤0.5% Rated Power(Without grid charger) |
||
Battery |
Battery type |
Lead Acid |
Equalization Voltage:56.4V; Floating Charge Voltage:54V |
Customization Battery |
Charging and discharging parameters for different types of batteries can be set on the operation panel |
||
Maximum Grid Charging Current |
60A |
||
Maximum PV Charging Current |
80A |
||
Maximum Charging Current(Grid+PV) |
80A |
||
Charging Methods |
Three-stage charging(constant current,constant voltage,floating charge) |
||
Protection |
Battery Undervoltage Alarm |
Defaut:44V |
|
Battery Undervoltage Protection |
Defaut:42V |
||
Battery Overvoltage Protection |
61VDC |
||
Overload Power Protection |
Automatic protection(Battery Mode),Breaker or fuse(Grid mode) |
||
Inverter Output Short-circuit Protection |
Automatic protection(Battery Mode),Breaker or fuse(Grid mode) |
||
Over-heating Protection |
≥90℃ shut down |
||
Operation Mode |
Grid priority/PV priority/Battery priority (optional) |
||
Conversion Time |
≤10ms |
||
Display |
LCD+LED |
||
Cooling |
Smart fan |
||
Communication Function(optional) |
RS232 connector/ USB/APP(WIFI or GPRS) |
||
Environment |
Operating Temperature |
-10℃~40℃ |
|
Storage Temperature |
-15℃~60℃ |
||
Noise |
≤55dB |
||
Altitude |
2000m |
||
Relative Humidity |
0%~95% ,Non-condensing |